- Flyback transformers for 30 Watt PoE applications
- Operating Frequency 250 kHz with input voltage 36 to 72 Volts
- Isolation 1500 Vrms, 60 seconds (Primary, Auxiliary to Secondary)
Electrical Parameters at 25 ºC
Power |
N/A 30 W |
Primary OCL (±10%) |
N/A 42 µH |
Maximum Primary Direct Current Resistance (DCR) |
N/A 0.060 mOhm |
Maximum Secondary Direct Current Resistance (DCR) |
N/A 0.0370 mOhm |
Maximum Auxiliary Direct Current Resistance (DCR) |
N/A 0.195 mOhm |
Maximum Primary Inductance LL |
N/A 0.43 µH |
Primary : Secondary Turns Ratio (±5 %) |
N/A 1 : 0.56 |
Primary : Auxiliary Turns Ratio (±5 %) |
N/A 1 : 0.33 |
Secondary Output Voltage |
N/A 19.5 V |
Secondary Output Current |
N/A 1.50 A |
Specifications
Industry Standards / Certifications |
N/A RoHS Compliant |
Isolation RMS Voltage (Vrms) |
N/A 1500 V |
Isolation Time |
N/A 60 s |
Operating Frequency |
N/A 250 kHz |
Standard Operating Temperature Range |
N/A -40 to +125 ºC |
Available Design |
N/A Custom |
Note
N/A
|