- Ideally suited for Dual Active Bridge (DAB) or Phase Shifted Full Bridge (PSFB) Transformer applications
- High efficiency and cost effective design and construction
- Suggested Cooling: Heat Sink or 120LFM forced air
                    Unit of Measure
                    
               
        
            Electrical Parameters at 25 ºC
| Input (VDC) | N/A 430 to 530 V | 
| Output (VDC) | N/A 33 to 56 V | 
| Maximum Output (ADC) | N/A 250 | 
| Switching Frequency | N/A 100 kHz | 
| Maximum Output Power | N/A 10000 W | 
| Minimum Primary Inductance | N/A 1800 µH | 
| Maximum Leakage Inductance (1-2) | N/A 14.0 µH | 
| Maximum Primary Direct Current Resistance (DCR) | N/A 15.0 mOhm | 
| Maximum Secondary Direct Current Resistance (DCR) | N/A 0.50 mOhm | 
| Primary : Secondary Turns Ratio (±3 %) | N/A 9:1 | 
Specifications
| Industry Standards / Certifications | N/A RoHS Compliant | 
| Available Design | N/A Custom | 
| Standard Operating Temperature Range | N/A -40 to +125 ºC | 
Note
| 
                                                                            N/A
                                                                             | 