MPS Industries, Inc.
Print Back
  • For RF, DS3/E3, Broadband, BPL and Ethernet Magnetics which require Supplementary or Reinforced Isolation
  • Construction complies with IEC60950 Isolation requirements
R3600 Series Wideband Isolation Transformers
Dimensional Drawing for R3600 Series Wideband Isolation Transformers
Unit of Measure
Items R3600 Series Wideband Isolation Transformers
R3600-1
500 Microhenry (µH) Minimum Inductance (1-4) R3600 Series Wideband Isolation Transformer
R3600 Series Wideband Isolation Transformers
R3600-2
800 Microhenry (µH) Minimum Inductance (1-4) R3600 Series Wideband Isolation Transformer
R3600 Series Wideband Isolation Transformers
R3600-3
120 Microhenry (µH) Minimum Inductance (1-4) R3600 Series Wideband Isolation Transformer
R3600 Series Wideband Isolation Transformers
R3600-4
120 Microhenry (µH) Minimum Inductance (1-4) R3600 Series Wideband Isolation Transformer
R3600 Series Wideband Isolation Transformers
R3600-5
200 Microhenry (µH) Minimum Inductance (1-4) R3600 Series Wideband Isolation Transformer
Turns Ratio (Primary : Secondary) (±5 %) N/A 1:1 N/A 1CT:1CT N/A 1:2 N/A 1:1:1 N/A 3:3:1
Minimum Inductance (1-4) N/A 500 µH N/A 800 µH N/A 120 µH N/A 120 µH N/A 200 µH
Maximum Direct Current Resistance (DCR) (1-4) N/A 0.30 Ohm N/A 0.50 Ohm N/A 0.20 Ohm N/A 0.20 Ohm N/A 0.30 Ohm
Maximum Insertion Loss (1 MHz) N/A -0.5 dB N/A -0.5 dB N/A -0.8 dB N/A -0.8 dB N/A -0.5 dB
Maximum Insertion Loss (100 MHz) N/A -1.0 dB N/A -1.2 dB N/A -1.0 dB N/A -1.0 dB N/A -1.0 dB
Typical Insertion Loss (300 MHz) N/A -2.6 dB N/A -3.5 dB N/A -1.5 dB N/A -1.5 dB N/A -3.0 dB
Hipot (Primary to Secondary) N/A 4500 Vrms N/A 3000 Vrms N/A 4500 Vrms N/A 4500 Vrms N/A 3000 Vrms
Schematic N/A B N/A A N/A B N/A C N/A C
Standard Operating Temperature Range1 N/A 0 to +70 ºC
Available Impedance Data N/A 50 Ohm75 Ohm
Industry Standards / Certifications N/A IEC60950 RoHS Compliant
Available Design N/A custom
Note N/A
  • OCL measured @ 100 kHz, 0.1 Vrms at Pin 1-4 (with 2-3 shorted)
  • Insertion Loss measured with 100 ohm as Input (Primary) Impedance between 1-4 and Output (Secondary) load with respective impedance
  • 50 Ohm and 75 Ohm impedance data available upon request
Product performance is limited to specified parameters. Data is subject to change without prior notice.

Dimensions
Unless otherwise specified, all tolerances are:
inch: .XX : ±0.015 .XXX : ±0.004
mm: X.X : ±0.38 X.XX : ±0.10
  • 1 Extended operating temperature available upon request.