  • Designed for use with the Linear Technology™ LT3799-1 LED Controller
Unit of Measure

Electrical Parameters at 25 ºC

Direct Current (DC) Input Voltage

80-265 V

Switching Frequency

100 kHz

Primary OCL (±10 %)

600 µH

Aux Output Voltage

20 V

Aux Output Current

0.01 A

Secondary Output Voltage

28 V

Secondary Output Current

0.5 A

Specifications

Standard Operating Temperature Range

-40 to +125 ºC

Isolation (Pri, Aux to Sec)

4500 Vrms

Isolation (Pri to Aux)

1250 Vrms

Industry Standards / Certifications

RoHS Compliant

Available Design

custom

Note

N/A

  • Primary OCL measured at 10 kHz, 0.1 Vrms