MPS Industries, Inc.
Print Back
  • Isolated flyback transformers with high output voltage
  • Ideal for use in medical applications
  • Input: 12-30 Vdc, Output: 1 kV - 2 kV
Unit of Measure

Electrical Parameters at 25 ºC

Power Output

N/A 70 W

Direct Current (DC) Input Voltage

N/A 18 V

Switching Frequency

N/A 60 kHz

Primary OCL (±10 %)(4-3)

N/A 8 µH

Maximum Primary Direct Current Resistance (DCR) (4-3)

N/A 10 mOhm

Turns Ratio (Primary : Secondary)(±3 %)

N/A 1 : 70

Maximum Secondary Direct Current Resistance (DCR) (8-12)

N/A 90 Ohm

Specifications

Industry Standards / Certifications

N/A RoHS Compliant

Standard Operating Temperature Range

N/A -40 to +85 ºC

Direct Current (DC) Isolation Voltage (Primary and Core to Secondary)

N/A 4000 V

Available Design

N/A custom

Note

N/A

  • Primary OCL (4-3) measured at 10 kHz, 0.1 Vrms
  • Hipot: 4000 Vdc, 0.5 mA, 5 s (Primary and Core to Secondary), 500 Vdc, 0.5 mA, 5 s (Primary to Core)
Product performance is limited to specified parameters. Data is subject to change without prior notice.

Dimensions
Unless otherwise specified, all tolerances are:
inch: .XX : ±0.015 .XXX : ±0.004
mm: X.X : ±0.38 X.XX : ±0.10